{"id":1659,"date":"2022-08-12T08:26:30","date_gmt":"2022-08-12T06:26:30","guid":{"rendered":"https:\/\/www.bst-biosensor.de\/laboratory\/"},"modified":"2024-09-13T13:18:59","modified_gmt":"2024-09-13T11:18:59","slug":"laboratory","status":"publish","type":"page","link":"https:\/\/www.bst-biosensor.de\/en\/laboratory\/","title":{"rendered":"Laboratory"},"content":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;4.18.0&#8243; _module_preset=&#8221;default&#8221; custom_padding=&#8221;0px||0px||true|false&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row _builder_version=&#8221;4.18.0&#8243; _module_preset=&#8221;default&#8221; max_width=&#8221;100%&#8221; max_width_tablet=&#8221;100%&#8221; max_width_phone=&#8221;100%&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.18.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_slider use_bg_overlay=&#8221;off&#8221; _builder_version=&#8221;4.27.0&#8243; _module_preset=&#8221;default&#8221; header_font=&#8221;|600|||||||&#8221; custom_button=&#8221;on&#8221; button_text_size=&#8221;18px&#8221; button_bg_color=&#8221;#0477BF&#8221; button_border_color=&#8221;#0477BF&#8221; button_icon=&#8221;&#x24;||divi||400&#8243; height_tablet=&#8221;50vh&#8221; height_phone=&#8221;50vh&#8221; height_last_edited=&#8221;on|phone&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_slide button_link=&#8221;@ET-DC@eyJkeW5hbWljIjp0cnVlLCJjb250ZW50IjoicG9zdF9saW5rX3VybF9wYWdlIiwic2V0dGluZ3MiOnsicG9zdF9pZCI6Ijc0OCJ9fQ==@&#8221; _builder_version=&#8221;4.27.0&#8243; _dynamic_attributes=&#8221;button_link&#8221; _module_preset=&#8221;default&#8221; background_enable_color=&#8221;off&#8221; use_background_color_gradient=&#8221;on&#8221; background_color_gradient_repeat=&#8221;on&#8221; background_color_gradient_stops=&#8221;rgba(153,158,186,0.3) 0%|rgba(153,158,186,0.19) 100%&#8221; background_color_gradient_overlays_image=&#8221;on&#8221; background_image=&#8221;https:\/\/www.bst-biosensor.de\/wp-content\/uploads\/BST_Key_Visual_9.jpg&#8221; background_enable_image=&#8221;on&#8221; global_colors_info=&#8221;{}&#8221; sticky_transition=&#8221;on&#8221;][\/et_pb_slide][\/et_pb_slider][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;4.18.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row column_structure=&#8221;1_2,1_2&#8243; use_custom_gutter=&#8221;on&#8221; gutter_width=&#8221;2&#8243; make_equal=&#8221;on&#8221; _builder_version=&#8221;4.25.2&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;3%||||false|false&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;1_2&#8243; _builder_version=&#8221;4.25.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.27.0&#8243; _module_preset=&#8221;default&#8221; header_font=&#8221;|600|||||||&#8221; header_font_size_tablet=&#8221;2rem&#8221; header_font_size_phone=&#8221;2rem&#8221; header_font_size_last_edited=&#8221;on|phone&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h1>Laboratory products<\/h1>\n<h4>LABTREND for glucose and lactate<\/h4>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.27.0&#8243; _module_preset=&#8221;default&#8221; custom_margin_tablet=&#8221;0.5rem||||false|false&#8221; custom_margin_phone=&#8221;0.5rem||||false|false&#8221; custom_margin_last_edited=&#8221;on|tablet&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h4>Flexible analyzer for laboratories of any size<\/h4>\n<p>The ideal glucose and lactate laboratory analyzer for EVERY facility,<br \/>regardless of the number of samples to be analyzed.<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.27.0&#8243; _module_preset=&#8221;default&#8221; custom_margin_tablet=&#8221;0.5rem||||false|false&#8221; custom_margin_phone=&#8221;0.5rem||||false|false&#8221; custom_margin_last_edited=&#8221;on|tablet&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h4>Effective and flexible<\/h4>\n<p>The innovative <strong>LABTREND<\/strong>, based on the high-quality BST reusable biosensors, works with interchangeable and expandable sample holders (racks). This means that both a single sample and countless samples can be measured effectively on the same device. This allows the <strong>LABTREND<\/strong> to adapt to the daily changing needs of a clinic.  <\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.27.0&#8243; _module_preset=&#8221;default&#8221; custom_margin_tablet=&#8221;0.5rem||||false|false&#8221; custom_margin_phone=&#8221;0.5rem||||false|false&#8221; custom_margin_last_edited=&#8221;on|tablet&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h4>Easy handling<\/h4>\n<p>The <strong>LABTREND<\/strong> analyzer is designed for use in clinical laboratories (screening), on hospital wards and in specialist diabetes practices (medical diagnosis) as well as in sports performance diagnostics due to its ease of use and accurate, real-time measurement procedure.<\/p>\n<p>[\/et_pb_text][\/et_pb_column][et_pb_column type=&#8221;1_2&#8243; _builder_version=&#8221;4.18.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_image src=&#8221;https:\/\/www.bst-biosensor.de\/wp-content\/uploads\/Labtrend-Analysator.jpg&#8221; title_text=&#8221;Labtrend Analyzer&#8221; _builder_version=&#8221;4.27.0&#8243; _module_preset=&#8221;default&#8221; hover_enabled=&#8221;0&#8243; global_colors_info=&#8221;{}&#8221; custom_margin_last_edited=&#8221;on|phone&#8221; custom_margin_phone=&#8221;1rem||||false|false&#8221; sticky_enabled=&#8221;0&#8243;][\/et_pb_image][\/et_pb_column][\/et_pb_row][et_pb_row use_custom_gutter=&#8221;on&#8221; gutter_width=&#8221;2&#8243; _builder_version=&#8221;4.25.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.25.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_accordion module_class=&#8221;striped-table&#8221; _builder_version=&#8221;4.27.0&#8243; _module_preset=&#8221;default&#8221; custom_padding=&#8221;||||false|false&#8221; db_closeable=&#8221;on&#8221; db_initial_state=&#8221;all_closed&#8221; border_color_all=&#8221;#4A5180&#8243; global_colors_info=&#8221;{}&#8221;][et_pb_accordion_item title=&#8221;Technical data&#8221; open=&#8221;on&#8221; open_toggle_text_color=&#8221;#000000&#8243; closed_toggle_text_color=&#8221;#4A5180&#8243; closed_toggle_background_color=&#8221;#FFFFFF&#8221; icon_color=&#8221;#4A5180&#8243; toggle_icon=&#8221;&#x4c;||divi||400&#8243; use_icon_font_size=&#8221;on&#8221; icon_font_size=&#8221;25px&#8221; open_icon_color=&#8221;#4A5180&#8243; open_use_icon_font_size=&#8221;on&#8221; open_icon_font_size=&#8221;25px&#8221; _builder_version=&#8221;4.27.0&#8243; _module_preset=&#8221;default&#8221; body_font_size=&#8221;15px&#8221; global_colors_info=&#8221;{}&#8221; toggle_text_color=&#8221;#FFFFFF&#8221; toggle_font=&#8221;|700|||||||&#8221; closed_toggle_font=&#8221;|700|||||||&#8221;]<\/p>\n<table class=\"striped-table\">\n<tbody>\n<tr>\n<td>Measuring principle<\/td>\n<td>Enzymatic &#8211; amperometric<\/td>\n<\/tr>\n<tr>\n<td>Sensor<\/td>\n<td>BST thick-film biosensor<\/td>\n<\/tr>\n<tr>\n<td>Measuring range<\/td>\n<td>glucose 0.5 &#8211; 50.0 mmol\/l (9 &#8211; 900 mg\/dl)<br \/>Lactate 0.5 &#8211; 40.0 mmol\/l (4.5 &#8211; 360 mg\/dl)<\/td>\n<\/tr>\n<tr>\n<td>Precision<\/td>\n<td>CV approx. 1.5 % at 12 mmol\/l<br \/>Glucose or lactate (n=20)<\/td>\n<\/tr>\n<tr>\n<td>Stability \/ drift<\/td>\n<td>approx. 3 % at 12 mmol\/l<br \/>Glucose or lactate (n=20)<\/td>\n<\/tr>\n<tr>\n<td>Lifetime of the sensor<\/td>\n<td>Glucose approx. 60 days or 8000 tests<br \/>Lactate approx. 60 days or 6,500 tests<\/td>\n<\/tr>\n<tr>\n<td>Sample material<\/td>\n<td>blood, plasma, serum<\/td>\n<\/tr>\n<tr>\n<td>Pr\u00e4analytik<\/td>\n<td>Verd\u00fcnnung 1 + 50<\/td>\n<\/tr>\n<tr>\n<td>Sample volume<\/td>\n<td>10 \u00b5l or 20 \u00b5l<\/td>\n<\/tr>\n<tr>\n<td>Interchangeable sample racks<\/td>\n<td>20 samples (or 19 + 1 emergency position) per rack<\/td>\n<\/tr>\n<tr>\n<td>Control rack<\/td>\n<td>1 calibration solution + 3 controls<\/td>\n<\/tr>\n<tr>\n<td>Reagent vessels<\/td>\n<td>1.5 ml or 2.0 ml<\/td>\n<\/tr>\n<tr>\n<td>Working temperature<\/td>\n<td>+15\u00b0C to +35\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Storage temperature<\/td>\n<td>-20\u00b0C to +70\u00b0C (without sensor)<\/td>\n<\/tr>\n<tr>\n<td>Humidity<\/td>\n<td>20 % &#8211; 95 %<\/td>\n<\/tr>\n<tr>\n<td>Calibration<\/td>\n<td>Automatic before each new rack<\/td>\n<\/tr>\n<tr>\n<td>Display<\/td>\n<td>Colored touchscreen<\/td>\n<\/tr>\n<tr>\n<td>Printer<\/td>\n<td>Thermal printer, integrated<\/td>\n<\/tr>\n<tr>\n<td>Languages<\/td>\n<td>English or German, other languages on request<\/td>\n<\/tr>\n<tr>\n<td>External connections<\/td>\n<td>RS 232 for connection to LIS\/KIS or external printer<\/td>\n<\/tr>\n<tr>\n<td>Memory<\/td>\n<td>600 results (first in &#8211; first out)<\/td>\n<\/tr>\n<tr>\n<td>Size (L x W x H)<\/td>\n<td>approx. 28 x 46 x 17 cm<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>approx. 6 kg<\/td>\n<\/tr>\n<tr>\n<td>Power supply<\/td>\n<td>230 V &#8211; 50\/60 Hz, via external 12 V mains plug<\/td>\n<\/tr>\n<tr>\n<td>Power consumption<\/td>\n<td>max. 30 VA <\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/et_pb_accordion_item][\/et_pb_accordion][et_pb_accordion module_class=&#8221;custom-li&#8221; _builder_version=&#8221;4.25.2&#8243; _module_preset=&#8221;default&#8221; toggle_text_color=&#8221;#4A5180&#8243; custom_padding=&#8221;||||false|false&#8221; db_closeable=&#8221;on&#8221; db_initial_state=&#8221;all_closed&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_accordion_item title=&#8221;Consumables for LABTREND&#8221; open=&#8221;on&#8221; open_toggle_text_color=&#8221;#000000&#8243; closed_toggle_text_color=&#8221;#4A5180&#8243; closed_toggle_background_color=&#8221;#FFFFFF&#8221; icon_color=&#8221;#4A5180&#8243; toggle_icon=&#8221;&#x4c;||divi||400&#8243; use_icon_font_size=&#8221;on&#8221; icon_font_size=&#8221;25px&#8221; open_icon_color=&#8221;#4A5180&#8243; open_use_icon_font_size=&#8221;on&#8221; open_icon_font_size=&#8221;25px&#8221; _builder_version=&#8221;4.25.2&#8243; _module_preset=&#8221;default&#8221; body_font_size=&#8221;15px&#8221; border_color_all=&#8221;#4A5180&#8243; global_colors_info=&#8221;{}&#8221; toggle_text_color=&#8221;#4A5180&#8243; toggle_font=&#8221;|700|||||||&#8221; closed_toggle_font=&#8221;|700|||||||&#8221;]<\/p>\n<ul>\n<li>BST reusable biosensor<br \/>Glucose: Article no.: 160 000000<br \/>Lactate: Article no.: 180 000000<\/li>\n<li>BST system solution, article no.: 06 000500<br \/>Glucose calibrator, article no.: 32 000050<br \/>Calibrator lactate, article no.: 46 000050<\/li>\n<li>Capillaries Article no.: 1800 001000<br \/>Reagent vessels, article no.: 16 001000<\/li>\n<\/ul>\n<p>[\/et_pb_accordion_item][\/et_pb_accordion][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Laboratory products LABTREND for glucose and lactateFlexible analyzer for laboratories of any size The ideal glucose and lactate laboratory analyzer for EVERY facility,regardless of the number of samples to be analyzed.Effective and flexible The innovative LABTREND, based on the high-quality BST reusable biosensors, works with interchangeable and expandable sample holders (racks). This means that both [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":50,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","inline_featured_image":false,"footnotes":""},"class_list":["post-1659","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.bst-biosensor.de\/en\/wp-json\/wp\/v2\/pages\/1659","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bst-biosensor.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.bst-biosensor.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.bst-biosensor.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bst-biosensor.de\/en\/wp-json\/wp\/v2\/comments?post=1659"}],"version-history":[{"count":6,"href":"https:\/\/www.bst-biosensor.de\/en\/wp-json\/wp\/v2\/pages\/1659\/revisions"}],"predecessor-version":[{"id":1743,"href":"https:\/\/www.bst-biosensor.de\/en\/wp-json\/wp\/v2\/pages\/1659\/revisions\/1743"}],"wp:attachment":[{"href":"https:\/\/www.bst-biosensor.de\/en\/wp-json\/wp\/v2\/media?parent=1659"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}